TBU Series Braking Unit for VFD

The function of the braking unit is to divert into a braking resistor the regenerative energy produced in the process of decelerating the motor, converting that energy into heat. Regenerative energy flows from the motor into the inverter DC Bus, manifested as increased bus voltage. The advantage gained using the DBU is improved braking performance and shorter deceleration time of the load.

General Details

Specifications

ModelSpecifications Usage Occasion Power Range Rated

Current

Peak

Current

General Mode
TBU-4T1L dynamic braking 0.75-22KW 6A 33A
TBU-4T1SA dynamic braking 30-55 KW 9A 50A
TBU-4T3SA dynamic braking 75-132 KW 10A 100A
TBU-4T3H dynamic braking 75-132 KW 40A 150A
TBU-4T4H dynamic braking 150-220 KW 50A 200A
TBU-4T5H dynamic braking 250-315 KW 60A 300A
TBU-4T6H dynamic braking 300-450 KW 70A 400A
Economical Mode
TBU-4T1G dynamic braking 30-55 KW 10A 50A
TBU-4T2G dynamic braking 75-132 KW 12A 100A
High-performance Mode
TBU-4T3HA dynamic braking 160-180 KW 70A 150A
TBU-4T4HA dynamic braking 220-250 KW 85A 200A
TBU-4T5HA dynamic braking 280-400 KW 120A 300A

Notice:

Rated current is maximum average current when braking unit working. Peak current is maximum current allowed during working, its running time should last less than 20 seconds.

Technical Info
Item Specification
Power supply Network

voltage

Tri-phase 220V/380V/460/660V(depend on models)
Network

frequency

45Hz~65Hz
Control Brake mode Automatic voltage trace
Reaction time Within 1mS, multiple noise filter

algorithm

Operation

voltage

Depend on different models
Hysteresis

voltage

less than 10V
Protection

function

Over-heat, over-current, short

circuit

Overheat

protection

75℃
Digit input port *1pcs, set up functions by

software

Digit input port *1pcs, set up functions by

software

Display and

Settings

Status indicator There are power indicator &

working indicator for all models.

And power indicator,

malfunctions indicator, fuse-break

indicator and brake-status

indicator for some models in

operation panel.

Operation

monitoring &

controlling

Some models with operation

panels have operation parameters

to monitor AC bus-bar voltage &

internal temperature etc.

Operation

voltage set-up

TBU-4T-3HA/4HA/5HA set up

via

operation panel, and others set up

when leaving factory.

Environment Installing place Indoor, elevation no more than

1000m, no sunshine, no

electro-conductive powder &

corrosive gas

temperature -10~40℃,well-ventilated
humidity Under 90%RH No dew
Vibration angle Under 0.5g